Pavilion
1 | 43.00° | 09-39-57-87 | Cut to PCP |
---|---|---|---|
2 | 43.93° | 06-42-54-90 | Cut to PCP, Locate Corner |
G1 | 90.00° | 12-24-36-60-72-84 | Set Length and Corners |
G2 | 90.00° | 96-48 | Meet at Corner |
3 | 55.89° | 96-48 | Meet 1-2-G1-G2 |
4 | 45.01° | 12-36-60-84 | Level Girdle |
5 | 48.01° | 24-72 | " |
6 | 47.01° | 03-45-51-93 | Meet G1-G2 |
7 | 43.00° | 21-27-69-75 | " |
Crown
A | 53.00° | 96-48 | Set Girdle Thickness |
---|---|---|---|
B | 37.00° | 03-45-51-93 | Meet at Corner |
C | 32.00° | 03-45-51-93 | Meet A-B |
D | 28.03° | 01-47-49-95 | Meet A-B-C |
E | 56.79° | 12-36-60-84 | Level Girdle |
F | 22.11° | 07-41-55-89 | Meet B-C-E |
G | 20.57° | 16-32-64-80 | Meet B-C-E-F |
H | 32.87° | 21-27-69-75 | Meet B-C-D-E-F |
I | 38.80° | 21-27-69-75 | Meet B-C-E-F-G-H-and Girdle |
J | 49.34° | 24-72 | Level Girdle |
T | 0.00° | Table |